LISTINGS AND CODE APPROVALS

LISTINGS AND CODE APPROVALS

THE BUILDERS BOX SERIES HAS BEEN TESTED AND APPROVED IN ACCORDANCE WITH THE

CSA xxxxxxx No.xxxxxxx STANDARDS FOR FIXED AND LOCATION

DEDICATED ELECTRIC ROOM HEATERS.

MODEL SPECIFICATIONS

MODEL

 

 

RATED POWER

REMOTE

 

NUMBER

DESCRIPTION

VOLTAGE

WATTS

CONTROL

AMPS

33EB304AAS

33” STANDARD

120/208/240

1440/2100/2700

YES

12.00/10.10/11.25

 

 

 

 

 

 

39EB364AAS

39” STANDARD

120/208/240

1440/2100/2700

YES

12.00/10.10/11.25

!!! WARNING !!!

THE INSTALLATION OF THE FIREPLACE UNIT MUST COMPLY WITH THE APPLICABLE LOCAL AND/ OR NATIONAL ELECTRICAL CODES AND UTILITY REQUIREMENTS.

THIS INSTALLATION SHOULD BE ENTRUSTED TO DULY QUALIFIED

PERSONNEL WHERE REQUIRED BY LAW.

STEP - BY - STEP INSTALLATION OVERVIEW

(please read all instructions before installation)

1)Rough in framing following the

recommended dimensions. (see figure 1) 2) Allow at least 8” of service cable for

connecting power supply wire to junction box on fireplace insert when installing before finishing wall. Allow up to 4 feet of service cable for connecting power supply wire to junction box on fireplace insert after finishing wall.

3)Remove the outer jacket and strip the individual conductors ½” from end.

4)Loosen the screw securing the junction box cover and remove the cover.

5)Place unit in position in the framed opening, level with shims if necessary

and attach unit to frame using mounting flanges provided ( see Section 3).

6)Wire a dedicated, properly fused circuit with a 15 amp rating for the appropriate voltage

(120, 208/240). (See table above)

7)Install wall thermostat as outlined on

page 10 section E

8)Place all connections inside the junction box. Secure the junction box cover on the unit.

When installing a cable clamp make sure it grips only the jacket of the service cable and thermostat wire.

!POWER SELECTION WARNING!

!

This unit is factory wired for 110 volt power supply.

!

If 208/240 volt operation is required, slide the voltage switch

and reconfigure the wiring accordingly (see figure 2).

 

Wires L1, L2, N & G are attached to the rear of

 

 

the junction box for easy access.

 

E-2

Page 2