Kunkle Safety and Relief Products
Models 910, 911, 912, 913, 916, 917, 918, 919, 920, 921 and 927
Models 910, 911, 912, 913, 916, 917, 918, 919
ASME VIII Liquid (English, GPM) - Flow Coefficient = 0.710
Set Pressure
(psig) D E F G H J
(0.1213) (0.2157) (0.3369) (0.553) (0.864) (1.415)
15 | 14 | 25 | 39 | 63 | 99 | 162 |
25 | 17 | 31 | 48 | 79 | 123 | 202 |
35 | 20 | 36 | 56 | 93 | 145 | 237 |
|
|
|
|
|
|
|
45 | 23 | 41 | 64 | 105 | 164 | 269 |
55 | 26 | 45 | 71 | 116 | 181 | 297 |
|
|
|
|
|
|
|
65 | 28 | 49 | 77 | 126 | 197 | 323 |
75 | 30 | 53 | 83 | 136 | 212 | 347 |
|
|
|
|
|
|
|
85 | 32 | 56 | 88 | 144 | 225 | 369 |
95 | 34 | 60 | 93 | 153 | 238 | 390 |
|
|
|
|
|
|
|
100 | 34 | 61 | 95 | 156 | 244 | 400 |
125 | 38 | 68 | 107 | 175 | 273 | 448 |
|
|
|
|
|
|
|
150 | 42 | 75 | 117 | 192 | 299 | 490 |
175 | 45 | 81 | 126 | 207 | 323 | 530 |
|
|
|
|
|
|
|
200 | 49 | 86 | 135 | 221 | 346 | 566 |
225 | 52 | 92 | 143 | 235 | 367 | 601 |
|
|
|
|
|
|
|
250 | 54 | 97 | 151 | 247 | 387 | 633 |
275 | 57 | 101 | 158 | 259 | 405 | 664 |
|
|
|
|
|
|
|
300 | 60 | 106 | 165 | 271 | 423 | 694 |
325 | 62 | 110 | 172 | 282 | 441 | 722 |
|
|
|
|
|
|
|
350 | 64 | 114 | 178 | 293 | 457 | 749 |
375 | 67 | 118 | 185 | 303 | 473 | 775 |
|
|
|
|
|
|
|
400 | 69 | 122 | 191 | 313 | 489 | 801 |
425 | 71 | 126 | 197 | 323 | 504 | 825 |
|
|
|
|
|
|
|
450 | 73 | 129 | 202 | 332 | 519 | 849 |
475 | 75 | 133 | 208 | 341 | 533 | 873 |
|
|
|
|
|
|
|
500 | 77 | 136 | 213 | 350 | 547 | 895 |
550 | 81 | 143 | 224 | 367 | — | — |
|
|
|
|
|
|
|
600 | 84 | 150 | 234 | 383 | — | — |
650 | 88 | 156 | — | — | — | — |
|
|
|
|
|
|
|
700 | 91 | 161 | — | — | — | — |
750 | 94 | 167 | — | — | — | — |
|
|
|
|
|
|
|
800 | 97 | 173 | — | — | — | — |
850 | 100 | 178 | — | — | — | — |
|
|
|
|
|
|
|
900 | 103 | 183 | — | — | — | — |
Notes
1.No code stamp or ‘NB’ on nameplate below 15 psig set.
2.Pressure Limitations
Model 910, 916: 3 to 900 psig
Model 911, 917: 3 to 900 psig
Model 912, 918: 3 to 300 psig
Model 913, 919: 3 to 900 psig
3.Liquid conversion factors to determine liquid capacity at other than 10% accumulation, multiply by the following:
1.022 = 15% accumulation
1.045 = 20% accumulation
1.066 = 25% accumulation (see page 20)
Tyco reserves the right to change product design and specifications | |