10. Fasten upper hinge to

unit (three screws).

Partially tighten screws.

See Figure 11.

7.Remove the bottom pivot plate from the door (two screws). Invert and install it on the top of the opposite side of the door.

11. Adjust door to assure

proper seal. Tighten

upper and lower hinge

screws securely.

12. Replace three plastic

plugs removed in Step 8

into holes on top of

unit. Replace screws in

holes in bottom of unit

on opposite side.

8. Locate the bushing saved

in Step 3. Holding the

bushing in place, lift the

door onto the newly

located bottom hinge

bracket. See Figure 14.

9. Onto the new top pivot

plate’s post, assemble the

bushing saved in Step 2

and the hinge plate saved

in Step 1. Install three

screws to attach new top

Door

Pivot Plate

Bushing

Figure 14

Stainless 15R Units and All 15WC Units

Note: The grille should not yet be installed. If it has been installed, remove it for door reversing. See Page 11.

hinge plate to cabinet.

10. Adjust door to assure proper seal.

Stainless 15R Refrigerator models and Black and Stainless 15WC Wine Captain models are reversible by moving the hinge hardware to the opposite side (Figure 12) as follows:

1.Remove the top hinge plate (three screws) from cabinet and save.

2.Remove the bushing from the top pivot plate’s post and save. See Figure 13.

3.Being careful not to lose the bottom pivot plate’s bushing (Figure 14), remove the door by lifting it off the bottom hinge bracket. Save the bushing.

Hinge

Plate

Hinge

Bracket

Figure 12

Other Site Requirements

Power Supply

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 10.

Environmental Requirements

The surrounding air temperature must be at least 50°F (10°C) but must not exceed 110°F (40°C). Units may be installed outdoors in a covered area. The unit must not be located near heat-generating equipment or in direct sunlight.

4.Remove bottom hinge bracket from cabinet (two screws). See Figure 5. Remove screws on opposite side of cabinet (Figure 6). Note that there may be a nut behind one or both screws on either side.

5.Install hinge bracket on opposite side, bottom of cabinet. See Figure 7.

Replace nut on back side where installed. Align hinge outer edge with cabinet before tightening screws.

6.Remove the top pivot plate from the door (two screws). Invert and install it on the bottom of the opposite side of the door.

Bushing