15R and 15WC Models
6 Prepare Power Supply
Electrical Specifications
CAUTION
7 Level the Unit
Leveling Information
Note: It is recommended that the unit is level.
Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.
See Figure 20 for recommended receptacle location.
1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (see Figure 21).
Check |
Level |
Figure 21 |
7" |
Figure 20 |
WARNING
SHOCK HAZARD — Electrical Grounding Required.
•Never remove the round grounding prong from the plug and never use a
•Never use an extension cord to connect power to the unit.
Go on to 7 Level the Unit.
2.If the unit is not level, adjust the feet on the corners of the unit as necessary (see Figure 22).
Turn Feet to Adjust |
Figure 22 |
3.Check the levelness after each adjustment and repeat the previous steps until the unit is level. Go on to
8 Install the Unit.
Installation Tip
If the room floor is higher than the floor in the
10 | 02/2005 |