2.Remove the screws securing the front access panel (Figure 31).

ICE CUBE THICKNESS

ADJUSTMENT

DIAL

5-

4-

3-

-

 

 

 

2

1 0 1-

4 5

2 3

DIAL IS FACTORY

SET TO “0”

CLRCO031

Figure 32

3.Locate the ice cube thickness adjustment dial on the control board (Figure 32). Turn the dial clockwise (+ number) to thicken or coun- terclockwise (- number) to thin the ice bridge.

Ice thickness adjustment dial should be turned only one increment (number on dial) at a time. Allow the ice maker to stabilize for 24 hours before making further adjust- ments. Since ice cubes in any given batch will vary, choose cubes from the sample area for comparison when making

adjustments (Figure 33). The factory setting is +1.