2.Remove the screws securing the front access panel (Figure 31).
ICE CUBE THICKNESS
ADJUSTMENT
DIAL
5- | 4- | 3- | - |
|
|
| 2 |
1 0 1-
4 5 | 2 3 |
DIAL IS FACTORY
SET TO “0”
CLRCO031
Figure 32
3.Locate the ice cube thickness adjustment dial on the control board (Figure 32). Turn the dial clockwise (+ number) to thicken or coun- terclockwise (- number) to thin the ice bridge.
Ice thickness adjustment dial should be turned only one increment (number on dial) at a time. Allow the ice maker to stabilize for 24 hours before making further adjust- ments. Since ice cubes in any given batch will vary, choose cubes from the sample area for comparison when making
adjustments (Figure 33). The factory setting is +1.
27