U-Line CO2175DWR manual Troubleshooting Guide, Danger, Electrocution Hazard

Models: CO2175DWR

1 20
Download 20 pages 26.54 Kb
Page 16
Image 16
Troubleshooting Guide

Troubleshooting Guide

ELECTROCUTION HAZARDDANGER

ELECTROCUTION HAZARD

Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected.

Troubleshooting - What to check when problems occur:

PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

Unit does not operate and

No electrical supply

Plug unit in or check circuit breaker.

electronic display is blank.

 

 

 

 

 

No interior light.

Loose or burned out bulb.

Tighten or replace bulb (See MAINTENANCE; LIGHT

 

 

BULB REPLACEMENT).

 

 

 

Electronic display is blank and

Unit is in blackout/Sabbath mode

Exit blackout/Sabbath mode (not Star K certified)

interior light is OFF with door OPEN.

(not Star K certified).

(See OPERATION; INTERIOR LIGHT CONTROL).

 

 

 

Electronic display is blank and

A display function has changed.

Touch and hold the warmer temperature button and

interior light is ON with door OPEN.

 

touch and release the POWER button three times, then

 

 

release the temperature button. The display should

 

 

become visible.

 

 

 

Electronic display shows repeating,

A factory control mode has been

Touch and hold the warmer temperature button and

randomly flashing symbols and

inadvertently entered.

touch and release the LIGHT button three times, then

partial characters.

 

release the temperature button to exit the factory

 

 

control mode. The set-point temperature should now

 

 

be displayed.

 

 

 

Electronic display shows:

A factory control mode has been

Repeatedly touch the warmer temperature button to

0, 1 to 26, or 99.

inadvertently entered.

advance any number shown to 99 and touch and

 

 

release the LIGHT button. The set-point temperature

 

 

should now be displayed.

 

 

 

Electronic display shows E3 or E10.

Drawer(s) open longer than 20

Close drawer(s) completely. The set-point temperature

 

minutes

should now be displayed.

 

 

 

Electronic display shows one or

The unit is displaying an error code.

Record the error code(s) displayed and call for service.

more of the following:

 

 

E1, E2, E4, E5, E6, E7, E8, E9, E11, P1.

 

 

 

 

 

Unit not cold enough. Check

Control set too warm

Set control to a cooler setting (See OPERATION). Allow

temperatures (See OPERATION for

 

24 hours for temperature to stabilize.

approximate temperatures).

 

 

Airflow to front grille blocked

Airflow must not be obstructed to front grille (See

 

 

 

OPERATION).

 

 

 

 

Dirty condenser coils

Clean condenser (See MAINTENANCE; CONDENSER

 

 

CLEANING).

 

 

 

 

Door gasket not sealing properly

Door adjustment required (See MAINTENANCE; DOOR

 

 

ALIGNMENT CHECK AND ADJUSTMENT).

 

 

 

 

Item(s) interfering with drawer

Reposition or remove item(s).

 

closing

 

 

 

 

 

Inaccurate temperature reading

Properly check temperature (See OPERATION).

 

 

 

Freezer section too warm

Drawer(s) not closed

Be sure drawer(s) is closed correctly.

 

 

 

 

Drawer(s) not closed correctly

Be sure drawer(s) is closed correctly.

 

 

 

Fresh food section too cold

Drawer(s) not closed correctly

Be sure drawer(s) is closed correctly.

 

 

 

 

Temperature control set too cold

Set temperature controller to warmer setting (See

 

 

OPERATION). Allow 24 hours for temperature to

 

 

stabilize.

 

 

 

 

Inaccurate temperature reading

Properly check temperature (See Operation).

 

 

 

16

CO2175DWR

Page 16
Image 16
U-Line CO2175DWR manual Troubleshooting Guide, Danger, Electrocution Hazard