12.Adjust door to assure proper seal. Tighten upper hinge screws securely.
13.Replace three plastic plugs removed in step 8 into holes on top of unit. Replace screws in holes in bottom of unit, opposite side.
14.Reinspect door seal and alignment. Adjust if needed.
15.Reinstall grille (one screw).
NOTE
On Combo Model 75A
To reverse the door mounting on Models Combo 75A and 75R (except Stainless Steel models) perform the following:
1.Remove grille (one screw) (Figure 22).
2.Remove top hinge from cabinet (four screws) (Figure 23). Hold door to keep it from falling.
3.Lift the door off the bottom hinge.
4.Remove four plastic plugs in hinge holes, top of cabinet, opposite side (Figure 29). Be careful not to scratch cabinet.
5.Remove pivot screw from top
hinge, invert screw and reinstall pivot screw in top hinge (Figure 28). Do not install hinge on cabinet at this time.
6.Remove bottom hinge from cabinet (four screws) and
screws on opposite side of cabinet (Figure 31).
7.Remove pivot screw from bot- tom hinge, invert screw and reinstall pivot screw in hinge
(Figure 28). | UL128 |
|
Figure 31
29