Show Control Operation

Show Control Operation

Show control is achieved by connecting a “Dry” or zero voltage contact to the show control terminals. The Power Fog Industrial requires no power to signal the fog, only one set of contacts that close for the entire fogging cue.

For Show Control Operation, the DMX Address must be set on 555. Closing the Show Control Remote terminals with dry contacts, triggers the following machine functions:

C + 1 = On/ Off w/ Variflow C + 2 = LSG On

C + 3 = Air Option

Optional Timer/ Duration Remote Operations

The Timer/ Duration Remote offers Duration, Interval, Variflow and fog on/ off controls.

Timer/ Duration Remote LED Indicator

Closed “Dry” Contact

Show Control

The Timer/ Duration Remote Handset was designed to indicate operation modes. These are as follows:

Slow Flashing Light: Indicates unit is not ready to operate but still in heating mode, fog is not available at this point.

Quick Flashing Light: Indicates unit is ready to operate but still in heating mode, some fog is available at this point.

Solid Light: Indicates that the unit is ready to fog at full output.

Duration

Variflow

Manual Fog

On/ Off Switch

Interval

LED

No Light: Indicates problems; a loss of power or remote is not connected. If these fail to correct the problem, contact your local Ultratec Special Effects dealer.

Note: To operate the LSG MK II using the Timer/ Duration Remote, the DMX Address must be set on 555 and the Duration control set over 50%. If the Duration is set at anything less than 50%, the Switched Power Port will be off. The Interval Knob works in the same fashion for machines equipped with the Air Option. The Show Control Remote and Timer/ Duration Remote cable may be extended from the machine and operated effectively away from the Power Fog Industrial. The maximum recommended cable length is 225 Feet.