IINSPECTION

IINSPECTION

Remove the Hygeaire ® fixture from its shipping carton. Inspect the fixture, and wire leads for damage. Do not oper- ate if there is any damage to the fixture, and/or wire leads. Lamp(s) are packed separately, to ensure maximum protec- tion to the lamp(s). Keep the lamp(s) aside until ready for installation. When installing lamp(s) into the fixture, exercise care not to touch the lamp's glass. Oils deposited, from fingers, on the glass could effect ultraviolet transmission.

The Hygeaire ® Model LIND 24-EVO fixture includes:

1 - Model LIND 24-EVO single lamp fixture with 6 inch lead wires

1 - Germicidal Ultraviolet Lamp

1 - Operating Instructions

The Hygeaire ® Model LIND 24-EVO-2PM fixture includes:

1 - Model LIND 24-EVO-2PM dual lamp fixture with 4 ½ foot lead wires

1 - Pendant Mounting Kit, consisting of:

1 - #19 Crossbar

1 - #11 Canopy

2 - 3/8" IP Stems 18 inches long

2 - #14 3/8" IP Slip Rings

6 - #22 3/8" IP Locknuts

2 - Germicidal Ultraviolet Lamps

1 - Operating Instructions

INSTALLATION

LOCATION

The Hygeaire ® fixture is recommended for use in rooms with good ventilation, with a ceiling height of 9 feet or more and where occupants remain for prolonged periods.

Access to the room does not need to be controlled while the fixture is operating.

The louver panels of the Hygeaire ® fixtures protect room occupants from ultraviolet exposure, by directing ultraviolet radiation into the upper areas of the room.

Any plans for the installation of the Hygeaire ® fixtures, should take into account the reflectance of the ceiling. Some finishes may have reflectances that are objectionably high, making exposure of more than a few hours unsafe. If any help is needed in determining the reflectance of a surface, please contact the Factory.

Ultraviolet energy, produced by the germicidal lamp(s), can fade some colors and/or alter the surface of some materials especially those directly irradiated by the lamp(s). If any help is needed in determining the ultraviolet resistance of any material, please contact the Factory.

The Hygeaire ® LIND 24-EVO fixture is designed to mount horizontally on a vertical surface, or wall, approximately 6 ½ to 7 feet above the floor.

The Hygeaire ® LIND 24-EVO-2PM fixture includes pendant hardware to suspend fixture from the ceiling. Standard stem pipe length is 18 inches. Other lengths are available, contact the Factory with requirements.