INSTALLATION OF LIND 24-EVO

INSTALLATION

INSTALLATION OF LIND 24-EVO

Figure 1 - LIND 24-EVO Installation

1.The fixture is to be mounted on a plumb, vertical surface, at a minimum height of 6 ½ to 7 feet from the floor. Installation must be able to support approximately 16 pounds.

2.Remove thumbscrews and open fixture to expose interior lamp holders and reflectors.

3.Remove one mounting screw from each end of the reflector so that the reflector will be able to pivot toward the lamp holder.

4.Pivot reflectors, on remaining screws, to expose the rear mounting holes and 7/8-inch wire access hole.

5.All wiring should confirm to state and local electrical codes as well as the current National Electrical Code (NEC).

6.After mounting and wiring, pivot reflectors back into place and replace mounting screws. Install lamp (packed separately), close fixture and replace thumbscrews.