UB343ZH_UBC785XLT_OM_0622 6/22/06 3:01 PM Page 37
•Tone Lock (out) mode
You can lock a particular subaudible tone. The scanner won't stop on any transmissions which have the locked out subaudible tone.
To select the SQ mode:
1.Press MENU.
2.Select 3:SYSTEM OPTION / 8:SQ MODE by rotating the VFO and pressing E.
3.Rotate the VFO to select one the type from (1:CSQ, 2:TONE SQ, 3:TONE SEARCH) and press E.
4.To set Tone Lock mode, do the following first, then select 2:TONE SQ in step 3.
1)For Scan mode, select 2:SCAN OPTION - select the channel number
2)For Search mode, select 1:SERVICE OPTION / :CHAIN SEARCH /
5:TONE DATA / 1:CTCSS or 2:DCS by rotating the VFO and pressing E, than press L/O.
☞Remember! You can also use ▲ or ▼ instead of rotating the VFO. Also instead of pressing E, you can press the VFO control.
Note: • To unlock the tone, press E instead of pressing L/O on step 1) or 2).
•CTCSS: Continuous Tone Coded Squelch System.
•DCS: Digital Coded Squelch.
•When Search mode and Tone Search are selected, the display shows the frequency and tone data alternately.
•If the delay feature
37