LP Gas Outdoor Fire Bowl Model No. GLT1332SP

Operating Instructions

Checking for Leaks

WW WARNING: Before using this outdoor fire bowl, make sure you have read, understand and are following all information provided in the Dangers and Warnings presented on page 2. Failure to follow those instructions can cause death, serious injury or property damage.

Burner Connections

1.Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.

Note: If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.

WW WARNING: Failure to inspect

Figure 5

 

 

this connection or follow these

 

 

instructions could cause a fire or an

 

 

explosion which can cause death,

 

 

serious bodily injury, or damage to

 

 

property.

 

2.

Please refer to diagram for proper installation.

 

3.

If the burner pipe does not rest flush to the

 

 

orifice, please contact 1.800.762.1142 for

 

 

assistance.

 

Tank/Gas Line Connection

 

1.

Make 2-3 oz. of leak solution by mixing one

Figure 6

 

 

part liquid dishwashing soap with three parts

 

 

water.

 

2.

Make sure control knob is “OFF .” (Figure 6)

OFF

3.

Connect LP gas tank per “Connect LP Gas

ARRÊT

 

Tank” instructions.

 

 

4.

Spoon several drops of solution, or use squirt

 

 

bottle, at all “X” locations (Figure 5).

 

 

a.

If any bubbles appear remove the LP gas

 

 

 

tank and reconnect, making sure the

 

 

 

connection is secure.

 

 

b.

If you continue to see bubbles after

 

 

 

several attempts, remove the LP gas

 

 

 

tank per “Disconnect LP Gas Tank”

Figure 7

 

 

instructions, and contact 1.800.762.1142

 

for assistance.

c.If no bubbles appear after one minute, wipe away solution and proceed.

Lighting Instructions

WW Caution: Keep outdoor fire bowl area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

WW Caution: Do not obstruct the flow of combustion and ventilation air.

Figure 8

1. Make sure all labels, packaging and protective films have been removed from the grill.

2. Make sure there are no obstructions of airflow to the gas unit. Spiders and insects can nest within and clog the burner / venturi tube at the orifice.

3. Connect LP gas tank per “Connect LP Gas Tank” instructions.

4. The control knob must be in the “OFF ” position (Figure 6).

5. Wearing Heat reistant gloves, position the lit

long match or lit long butane lighter near the side of the burner. (Figure 7)

6. Turn control knob counterclockwise to (HIGH).

7. Remove long match/long butane lighter.

8. Turn the control knob to (HIGH).

9. If ignition does not occur in 5 seconds, turn regulator/control knob to “OFF” position, wait 5 minutes and repeat lighting procedure.

10. After lighting, observe the burner flame. Make sure all burner ports are lit and flame height matches illustration (Figure 8).

WW Caution: If burner flame goes out during operation, immediately turn

the gas “OFF” and let the gas clear for about 5 minutes before re- lighting.

Turning Off

1.Turn control knob to the “OFF ” position (Figure 6).

2.Disconnect LP gas tank per “Disconnect LP Gas Tank” instructions and properly store tank.

Cleaning and Care

WW Caution:

1.All cleaning and maintenance should be done when outdoor fire bowl is completely cool and with the LP gas tank disconnected.

2.DO NOT clean any outdoor fire bowl part in a self cleaning oven. The extreme heat will damage the finish.

Notices

1.Abrasive cleaners will damage this product.

2.Never use oven cleaner to clean any part of outdoor fire bowl.

Before Each Use:

1.Keep the outdoor fireplace area clean and free from any combustible materials, gasoline, and other flammable vapors and liquids.

2.Do not obstruct the flow of the combustion of LP and the ventilation air.

3.Keep the ventilation opening(s) of the LP gas tank area free and clear from debris.

4.Visually check the burner flames to make sure your outdoor fireplace is working properly.

5.See sections below for proper cleaning instructions.

6.Check all gas connections for leaks.

7.Check components for any signs of damage or rust.

8.Check and clean the burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire beneath the outdoor fireplace.

9.If damage to any component is detected, do NOT operate until repairs are executed.

Cleaning Surfaces

1.Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water.

2.For stubborn surfaces use a citrus based degreaser and a nylon scrubbing brush.

3.Rinse clean with water.

4.Allow to air dry.

Before Storing

1.Turn control knob to (OFF) and remove LP gas tank, per “Disconnect LP Gas Tank” instructions. Wait for outdoor fireplace to fully cool (about 45 min.).

2.Clean all surfaces.

3.If storing the outdoor fireplace indoors, disconnect the LP tank (see “Disconnect LP Gas Tank” section) and leave the LP gas tank OUTDOORS.

4.Place the protective cap cover on the LP tank and store the tank outdoors in a well ventilated area out of direct sunlight.

5.Cover outdoor fireplace with a durable vinyl cover designed to fit this unit.

6.If storing the outdoor fireplace outdoors, cover the outdoor fireplace with a cover for protection from the weather.

Product Registration

For faster warranty service, register your product immediately at www.BlueRhino.com or call 1.800.762.1142.

Replacement Parts

Replacement parts can be found at parts.BlueRhino.com or call 1.800.762.1142.