Unigreen DEVIL Tables For Calibrating Cannons, Tabella erogazione in Litri/ettaro Cannone Ø400

Models: AP APC DEVIL serie EOLO EXPO SIRIO

1 40
Download 40 pages 61.3 Kb
Page 33
Image 33
Manual background

TABLES FOR CALIBRATING CANNONS

TABLES FOR CALIBRATING CANNONS Ø400-455TILTING HEAD

 

 

 

 

 

Tabella erogazione in Litri/ettaro Cannone Ø400

6 getti Testa Snodata

 

unigreen spa

 

 

 

 

Lt./ha spreading rate table for Cannone Blower Ø4005 6 NOZZLES Tilting Head

 

 

 

 

 

 

 

 

Piastrina ceramica Ø1,8

 

 

Piastrina ceramica Ø2

 

 

Gittata

 

PRESSIONE bar

10

15

20

25

30

40

50

10

15

20

25

30

40

50

 

spray distance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Km/hVelocità

 

3,5

441

538

624

699

761

878

987

480

590

679

761

830

960

1197

 

 

 

peeds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Litri/ha

 

 

 

 

4

386

471

546

612

666

768

864

420

516

594

666

726

840

1047

 

15

 

 

 

5

309

377

437

490

533

614

691

336

413

475

533

581

672

838

 

 

 

 

6

257

314

364

408

444

512

576

280

344

396

444

484

560

698

 

15 m.

 

 

 

7

221

269

312

350

381

439

494

240

295

339

381

415

480

598

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Km/hVelocità

 

3,5

368

449

520

583

634

731

823

400

491

566

634

691

800

997

 

 

 

peeds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Litri/ha

 

 

 

 

4

322

393

455

510

555

640

720

350

430

495

555

605

700

873

 

18

 

 

 

5

257

314

364

408

444

512

576

280

344

396

444

484

560

698

 

 

 

 

6

214

262

303

340

370

427

480

233

287

330

370

403

467

582

 

 

 

 

 

7

184

224

260

291

317

366

411

200

246

283

317

346

400

499

 

18 m.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Km/hVelocità

 

3,5

288

351

407

456

496

572

644

313

385

443

496

541

626

780

 

 

 

peeds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Litri/ha

 

 

 

 

4

252

307

356

399

434

501

563

274

337

387

434

473

548

683

 

23

 

 

 

5

201

246

285

319

347

401

451

219

269

310

347

379

438

546

 

 

 

 

6

168

205

237

266

290

334

376

183

224

258

290

316

365

455

 

23 m.

 

 

 

7

144

176

203

228

248

286

322

157

192

221

248

271

313

390

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tab. 3215/0000F

 

 

 

Litri/min.

39

47

55

61

67

77

86

42

52

59

67

73

84

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ug. sing.

6,44

7,85

9,10

10,20

11,10

12,80

14,40

7,00

8,60

9,90

11,10

12,10

14,00

17,45

 

 

N.B. to obtain better agitaton in the tank, verify that the total lt/min. spray delivery does not exceed 75% of the pump delivery. For example, with an APS 121 select a maxium setting of 86 lt/min.

N.B. to calculate the different ranges extension it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.3, page 20).

 

 

 

 

 

Tabella erogazione in Litri/ettaro Cannone Ø455

6 getti Testa Snodata

 

unigreen spa

 

 

 

 

Lt./ha spreading rate table for Cannone Blower Ø455 6 NOZZLES Tilting Head

 

 

 

 

 

 

 

 

Piastrina ceramica Ø1,8

 

 

Piastrina ceramica Ø2

 

 

Gittata

 

PRESSIONE bar

10

15

20

25

30

40

50

10

15

20

25

30

40

50

 

spray distance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Velocità Km/h

 

3,5

331

404

468

525

571

658

741

360

442

509

571

622

720

897

 

 

 

speed

4

290

353

410

459

500

576

648

315

387

446

500

545

630

785

Litri/ha

20

 

5

232

283

328

367

400

461

518

252

310

356

400

436

504

628

 

6

193

236

273

306

333

384

432

210

258

297

333

363

420

524

 

 

 

7

165

202

234

262

285

329

370

180

221

255

285

311

360

449

 

20 m.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3,5

221

269

312

350

381

439

494

240

295

339

381

415

480

598

 

 

 

 

 

4

193

236

273

306

333

384

432

210

258

297

333

363

420

524

 

30

 

 

 

5

154

188

218

245

266

307

346

168

206

238

266

290

336

419

 

 

VelocitàKm/h

eedsp

6

129

157

182

204

222

256

288

140

172

198

222

242

280

349

Litri/ha

 

 

 

7

110

135

156

175

190

219

247

120

147

170

190

207

240

299

 

30 m.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Velocità Km/h

 

3,5

184

224

260

291

317

366

411

200

246

283

317

346

400

499

 

 

 

speed

4

161

196

228

255

278

320

360

175

215

248

278

303

350

436

Litri/ha

36

 

5

129

157

182

204

222

256

288

140

172

198

222

242

280

349

 

6

107

131

152

170

185

213

240

117

143

165

185

202

233

291

 

 

 

7

92

112

130

146

159

183

206

100

123

141

159

173

200

249

 

36 m.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tab. 3215/0000F

 

 

 

Litri/min.

39

47

55

61

67

77

86

42

52

59

67

73

84

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ug. sing.

6,44

7,85

9,10

10,20

11,10

12,80

14,40

7,00

8,60

9,90

11,10

12,10

14,00

17,45

 

 

N.B. to obtain better agitaton in the tank, verify that the total lt/min. spray delivery does not exceed 75% of the pump delivery. For example, with an APS 121 select a maxium setting of 86 lt/min.