United States Stove AUTOMATIC COAL BURNING MODEL 2827 - EXTERIOR, Repair Parts, Heater, 6 5 4

Models: 2827

1 10
Download 10 pages 58.73 Kb
Page 5
Image 5
AUTOMATIC COAL BURNING MODEL 2827 - EXTERIOR

AUTOMATIC COAL BURNING MODEL 2827 - EXTERIOR

REPAIR PARTS

CIRCULATOR

 

9

10

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

N

O

W

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

C

R

E

 

 

11

12

13

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

7

CHIMNEY CONNECTION

Two basic types of chimneys are approved for use with solid fuel: Factory-built and masonry. Factory-built chimney must comply with UL103HT standard.

Do not expect your stove or furnace to create draft. Draft is not a function of the appliance. Draft is purely a function of the chimney. Modern stoves and furnaces are much more airtight and efficient than those of the past; and, therefore require greater draft. A minimum of .05, measured in water column (gauges to measure chimney draft are readily available at stove shops and are economical to purchase or rent) is required for proper drafting to prevent back-puffing, smoke spillage, and to maximize performance.

Chimneys perform two functions - one of which is apparent: The chimney provides a means for exhausting smoke and flue gases resulting from combustion of the fuel. Secondarily, though, the chimney provides "Draft" which allows oxygen to be continuously introduced into the appliance, so that proper combustion is possible. As of April 1, 1987, all heaters and furnaces manufactured by United States Stove Company should be installed using a factory built chimney that meets the "Type HT" requirement of UL 103 (when a factory - built chimney is used).

IMPORTANT

*Size the chimney to the flue outlet on the stove. (6" outlet = 6" I.D. chimney) *Avoid using elbows except as necessary (they reduce draft).

*Make sure all horizontal runs of connector pipe go up hill (1/4" elevation for each horizontal foot).

CHIMNEY CAP MANDATORY

HEATER

6REPAIR PARTS

5

4

2

1

15

16

14

17

18

19

3

NON-COMBUSTIBLE

 

WALL

 

THIMBLE

 

COLLAR

 

PIPE

 

CAST IRON DAMPER

 

BAROMETRIC

DRAFT CONTROL

(OPTIONAL)

FLOOR PROTECTOR

CLASS A UL 103HT

 

CHIMNEY KIT INCLUDING

 

WALL THIMBLE.

 

2 FT MIN.

 

10 FT.

3 FT.

11 FT. MIN.

MIN.

 

 

 

REFER TO CHIMNEY

MANUFACTURERS PARTS

AND INSTRUCTIONS

PIPE

CAST IRON DAMPER

BAROMETRIC

DRAFT CONTROL

(OPTIONAL)

FLOOR PROTECTOR

Fig. 5

Fig. 6

16

5

Page 5
Image 5
United States Stove owner manual AUTOMATIC COAL BURNING MODEL 2827 - EXTERIOR, Repair Parts, Heater, Circulator, 6 5 4