LOCATING THE HEATER
AS A LOCATION IS SELECTED, KEEP THE FOLLOWING IN MIND:
1.The chimney connection should be as possible. The heater must have its own chim- ney. Do not connect this unit to a chimney flue, serving another appliance. If there is no chim- ney near where you wish to place the heater, you can use a UL 103HT Residential Type and Building Heating Appliance Chimney (Fig. 5 &6).
NOTE: BEFORE FIRING
HEATER
Slide firebricks toward the rear
so no gaps remain between
them.
REPAIR PARTS LIST - MODEL 2827 (SEE PAGE 18)
AUTOMATIC COAL BURNING CIRCULATOR
|
| Key No. | Description | Qty. | Part No. |
|
1 | Shaker | 1 | 40045 |
| ||
| 2 | Second Heat Shield Assembly | 1 | 22030 |
| |
3 | Heat Shield | 1 | 22110 |
| ||
4 | Draft Damper Hinge Pin | 1 | 17200 |
| ||
5 | Draft Damper Frame | 1 | 40075 |
| ||
* | 4 | 83086 |
| |||
* | 4 | 83250 |
| |||
| 6 | Base | 1 | 67859 |
| |
7 | Draft Control Damper | 1 | 67132 |
|
2.Place the heater on solid masonry or solid concrete. When the heater is used on a com- bustible floor protector of one layer of 3/8" millboard having a thermal conductivity of K=0.84 BTU in./ft. 2 hr. Deg. F with
3.Check Figures 2, 3, and 4. Be sure you have the clearances shown from the heater and the connector pipe to combustible surfaces. If you have a solid brick or stone wall behind your heater, you can place the heater as close as you wish to the wall. If the wall is only faced with brick or stone, treat it as a combustible wall.
CAUTION:
Keep furnishings and other combustible materials away from the heater.
| 8 | Clip | 1 | 83818 |
|
| 9 | Coal Grate | 1 | 40101 |
|
| 10 | Grate Support | 2 | 22536 |
|
| * | 8 | 83086 |
| |
| * | Nut | 8 | 83250 |
|
| 11 | Firebrick | 10 | 89066 |
|
| 12 | Firebox | 1 | 67858 |
|
| 13 | Front & Back Liner | 3 | 40100 |
|
| 14 | Flue Collar | 1 | 40246 |
|
| 15 | Flue Collar Gasket | 1 | 88032 |
|
| 16 | Firebrick Retainer | 2 | 40132 |
|
| * | 6 | 83227 |
| |
| * | 6 | 83250 |
| |
| * | Smoke Curtain Bracket | 2 | 22171 |
|
| * | 2 | 83250 |
| |
| * | Machine Screw | 2 | 83086 |
|
| 17 | Hinge Pin | 1 | 83872 |
|
| 26" |
|
|
Fig. 2 |
|
| 25" |
WONDERCOAL |
| Fig. 3 | |
|
|
| 35" |
|
| 16" | 12" |
|
|
|
54" | |
CONSTRUCTION IN | |
| ACCORDANCE WITH |
12" | NFPA 211 |
Fig. 4 |
| 36" |
|
| 19 1/4" |
|
| NOTE: DASHED LINES SHOW |
|
| STRAIGHT UP AND THROUGH |
|
| THE WALL INSTALLATION |
32 1/4" | 16" | 4 3/4" |
17" |
|
SIDEWALL FLOOR PROTECTOR (TOP VIEW)
18 | Smoke Curtain | 1 | 22090 |
| |
| 19 | Coal Grate Frame | 1 | 40102 |
|
20 | Feed Door Assembly | 1 | 68605 |
| |
21 | 2 | 83250 |
| ||
22 | Draft Wheel | 1 | 40056 |
| |
23 | Machine Screw | 1 | 83227 |
| |
| 24 | Door Handle | 2 | 40091 |
|
25 | Wood Handle | 1 | 89523 |
| |
26 | Feed Door Rope Gasket | 45" | 88033 |
| |
27 | Ash Door Assembly | 1 | 67781 |
| |
28 | 1 | 22434 |
| ||
29 | Washer, Flat | 2 | 83045 |
| |
30 | 2 | 83250 |
| ||
31 | Ash Door Gasket | 29" | 88033 |
| |
32 | Latch | 1 | 22108 |
| |
33 | Ash Pan | 1 | 67444 |
| |
* | 6 | 83086 |
| ||
* | 6 | 83250 |
| ||
34 | Latch Spacer | 1 | 21467 |
| |
35 | Hinge Pin (Long) | 1 | 83114 |
| |
|
|
|
|
| |
* | NOT SHOWN |
|
|
|
4 | 17 |