Installation

INSTALLATION OPTIONS

Read this entire manual before you install and use your King/Ashley stove. Failure to follow instructions may result in property damage, bodily injury, or even death!

(See specific installation details for clearances and other installation requirements)

A Freestanding Unit—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with clearance requirements for a freestanding stove installation.

An Alcove Unit—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with clearance requirements for an alcove installation.

Your King/Ashley stove may be installed to code in either a conventional or mobile home (see SPECIAL MOBILE HOME REQUIREMENTS).

It is recommended that only a authorized technician install your King/Ashley stove, preferably an NFI certified specialist.

IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the mal- function of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer if you have any questions.

FLOOR PROTECTION

This unit must be installed on a non-combustible floor surface. If a floor pad is used, it should be UL listed or equal. The floor pad or non-combustible surface should be large enough to extend a minimum of 6-inches in front, 6-inches on each side, and 1-inch behind the stove (see FIGURE 1).

Floor protection must extend under and 2-inches to each side of the chimney tee for an interior vertical installation (see FIGURE 2).

Your King/Ashley stove will need a minimum 31” x 38” floor protector. A Floor Protector of 1 inch thick is recommended for this installation.

USSC

PelletKing.com

5

 

Page 5
Image 5
United States Stove 5500/5500XL owner manual Installation Options, Floor Protection