United States Stove 5500/5500XL owner manual Installation, Vent Termination Clearances

Models: 5500/5500XL

1 20
Download 20 pages 40.41 Kb
Page 8
Image 8
VENT TERMINATION CLEARANCES:

Installation

VENT TERMINATION CLEARANCES:

A)Minimum 4-foot clearance below or beside any door or window that opens.

B)Minimum 1-foot clearance above any door or window that opens.

C)Minimum 3-foot clearance form any adjacent building.

D)Minimum 7-foot clearance from any grade when adjacent to public walkways.

E)Minimum 2-foot clearance above any grass, plants, or other combustible materials.

F)Minimum 3-foot clearance from an forced air intake of any appliance.

G)Minimum 2-foot clearance below eves or overhang.

H)Minimum 1-foot clearance horizontally from combustible wall.

Must be a minimum of 36-inches above the roof and 24-inches above the highest point or the roof within 10-feet.

I

A

FIGURE 6 B

CH

A

F

E Manual background

F

D

FIGURE 6

VENT TERMINATION CLEARANCES

8

PelletKing.com

USSC

 

Page 8
Image 8
United States Stove 5500/5500XL owner manual Installation, Vent Termination Clearances