VENT TERMINATION CLEARANCES:

Installation

VENT TERMINATION CLEARANCES:

A-----Minimum 4-foot clearance below or beside any door or window that opens.

B-----Minimum 1-foot clearance above any door or window that opens.

C-----Minimum 3-foot clearance from any adjacent building.

D-----Minimum 7-foot clearance from any grade when adjacent to public walkways.

E-----Minimum 2-foot clearance above any grass, plants, or other combustible materials.

F-----Minimum 3-foot clearance from a forced air intake of any appliance.

G-----Minimum 2-foot clearance below eaves or overhang.

H-----Minimum 1-foot clearance horizontally from combustible wall.

I------Must be a minimum of 36-inches above the roof and 24-inches above the highest point of the roof within 10-feet.