9947 SPECIFICATIONS
Natural Gas |
| Propane/LPG |
|
Manifold Pressure Setting: | 4" w.c. | Manifold Pressure Setting: | 10" w.c. |
Gas Inlet Pressure: Maximum | Gas Inlet Pressure: Maximum | 13" w.c. | |
Minimum | 5" w.c. | Minimum | 11" w.c. |
|
|
|
| Gas Rate | Number |
| |
| Model Number | Type | Max BTU/Hr | Min BTU/Hr | of Burners |
| |
|
| 9947N | Manual | 39,900 | 27,000 | 1 |
|
|
| 9947L | Manual | 39,900 | 27,000 | 1 |
|
|
|
|
|
| |||
Controls - Main control has 4 positions: |
|
|
| ||||
1. | OFF - All gas to the gas logs is shut off at the control |
|
| ||||
| 2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries | ||||||
3. | PILOT - Valve position to light/maintain a standing pilot |
|
| ||||
4. | ON - Gas flow to complete system. |
|
|
|
HIGH / LOW Control - Infinite control :
Rotate knob clockwise to LOW, counter clockwise to HIGH.
CONTENTS
9947L and 9947N Unvented Gas Heaters
1.Packet containing Homeowner's/Installation instructions.
2.Three (3) individually wrapped fiber ceramic logs, refer to installation instructions.
3.Unvented gas heater.
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
CAUTION
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE FRAGILE, HANDLE WITH CARE.
Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.
5