TROUBLESHOOTING
WARNING
Turn off and let cool before servicing. Only a qualified service person should service and repair heater.
NOTE: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM | POSSIBLE CAUSE |
| REMEDY | |
| • Ignitor electrode positioned wrong | • Replace | ignitor. | |
| • Ignitor electrode is broken | • Replace | ignitor. | |
| • Ignitor electrode not connected to ignitor | • Reconnect ignitor cable. | ||
When ignitor button is pressed, there is | cable. |
|
| |
|
|
| ||
no spark at ODS/Pilot. | • Ignitor cable pinched or wet keep ignitor | • Free ignitor cable if pinched by any metal | ||
| cable dry. | or tubing. | ||
| • Broken ignitor cable | • Replace ignitor cable. | ||
| • Bad piezo ignitor | • Replace piezo ignitor. | ||
|
|
| ||
| • Appliance burning vapors from paint, hair | • Ventilate room. Stop using | ||
Appliance produces unwanted odors. | spray, glues, etc. | products while heater is running. | ||
| • Gas leak. | • Locate and correct all leaks. | ||
|
|
|
| |
| • Not enough fresh air is available for ODS/ | • Open window and/or door ventilation | ||
| Pilot to operate. | |||
|
|
| ||
Appliance shuts off in use. | • Low line pressure. | • Contact local gas company. | ||
| ||||
|
|
| ||
| • ODS/Pilot is partially clogged. | • Clean ODS/Pilot. | ||
|
|
| ||
Gas odor even when control knob is in | • Gas leak. | • Locate and correct all leaks. | ||
OFF position. | • Control valve defective. | • Replace control valve. | ||
| ||||
|
|
| ||
| • Gas supply turned off or manual shutoff | • Turn on gas supply or open manual shutoff | ||
| valve. |
| ||
| valve closed. |
| ||
| • Turn control knob while in PILOT position. | |||
|
| |||
When ignitor button is pressed, there is | • Control knob not in PILOT position. | • Press in control knob while in PILOT posi | ||
| tion. |
| ||
spark at ODS/Pilot, but no ignition. |
|
| ||
• Control knob not pressed in while in Pilot | • Continue holding down control knob. | |||
| ||||
| position | Repeat igniting operation until air is re- | ||
| • Air in gas lines when installed. | moved |
| |
| • Replace ODS/pilot assembly or get is ser- | |||
|
| |||
|
| viced. |
| |
|
| • Replace gas regulator. | ||
|
|
| ||
| • Control knob not fully pressed in. | • Press in control knob fully. | ||
|
|
| ||
ODS/Pilot lights, but flame goes out | • Control knob not pressed in long enough. | • After ODS/pilot lights, keep control knob | ||
when control knob is released. | ||||
pressed in 30 seconds. | ||||
|
|
• Manual shutoff valve not fully open.
• Fully open manual shutoff valve.
20