Vermont Casting D232 Trouble Shooting The Gas Control System, Honeywell Millivolt Valve, Start

Models: D232

1 28
Download 28 pages 37.45 Kb
Page 22
Image 22
TROUBLE SHOOTING THE GAS CONTROL SYSTEM

TROUBLE SHOOTING THE GAS CONTROL SYSTEM

HONEYWELL MILLIVOLT VALVE

START

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• GAS SUPPLY ON

 

 

 

 

NO

 

 

 

 

 

• SUPPLY LINE HOOKED UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• SHUTOFF VALVE OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• LOCKOUT HAS ENGAGED. WAIT

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 SECONDS AND TRY AGAIN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• FOR SPARK AT ELECTRODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHILE DEPRESSING PIEZO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

— 1/8" GAP TO

PILOT LIGHTS WITH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

PILOT HOOD NEEDED.

PIEZO IGNITOR

 

 

 

 

 

 

 

 

• ALL WIRING CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• REPLACE PIEZO IGNITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

• FOR AIR IN THE LINES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• THERMOPILE NEEDS A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM 325mV. ADJUST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT FLAME HEIGHT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• ALL WIRING CONNECTIONS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT STAYS LIT

 

 

 

 

NO

 

 

 

 

 

• REPLACE THERMOPILE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• THERMOCOUPLE NEEDS A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM OF 14mV.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• DEFECTIVE VALVE. TURN TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT, METER SHOULD READ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GREATER THAN 100 mV. IF

YES

 

 

 

 

 

 

 

 

 

 

 

NOT, REPLACE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• VALVE IS TURNED ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• ON/OFF SWITCH IS NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TURNED ON. WATCH

PILOT LIGHTS MAIN

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

FOR GROUNDED WIRES!

BURNER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• THERMOPILE NEEDS A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM 325mV.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• PLUGGED BURNER ORIFICE.

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM OK.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 22 -

Page 22
Image 22
Vermont Casting D232 Trouble Shooting The Gas Control System, Honeywell Millivolt Valve, Start, Check