INSTALLATION OF REMOTE

When using copper or flex connector use only approved fittings. Always provide a union when using back iron pipe so that gas line can be easily disconnected for burner or fan servicing. See Fig. 2. See gas specification for pressure details and ratings.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing.

DO NOT USE THIS FIREPLACE IF ANY PART OF THIS FIREPLACE HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND TO REPLACE ANY PART CONTROL WHICH HAS BEEN UNDER WATER.

INSTALLATION OF REMOTE

SWITCH FOR RN/RP GAS VALVE

Install on/off switch assembly on either the rear right or left side of the Fireplace.

1.Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace.

2.Position switch assembly onto the back of the fireplace, then fasten two screws as shown in Fig. 5.

3.Attach wiring under the clips on the rear casing (Fig. 5) and install wiring through the rear opening of the fireplace before connecting to the valve as shown in Fig. 4.

VALVE

 

 

TPTH

 

 

THERMOPILE

 

 

TP

 

 

TH

 

 

 

 

P

 

I

T L

 

O

 

 

ON/OFF SWITCH OR

 

 

MILLIVOLT THERMOSTAT

 

 

TH

 

 

TP

 

 

TP TH

 

 

PILOT ADJ

 

 

Fig. 4

On/off switch

assembly

Clips

VALVE Screw (through existing hole)

Screw

Wiring for milli-volt gas valves

Fig. 5

- 6 -

Page 6
Image 6