IMPORTANT SAFETY INFORMATION
12.Do not place clothing or other flammable material near the appliance.
13.Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
14.Any safety screen or guard removed for servicing must be replaced prior to operating the heater.
15.This
16.Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. Refer to the National Fuel Gas Code.
17.The heater and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
18.The heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
19.Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
PRODUCT FEATURES
Features:
• Heating Efficiency - 99.9%
• Wide BTU Range: 8,000 - 30,000.
• Safe Operation - Oxygen Depletion Sensor (ODS).
•No Electricity Required.
•Fiber Ceramic Logs.
•
•Clean Operation.
• Wide Bay Front.
•Compact Design.
•Easy Operation.
•Heats up to 1,000 square feet.
FIGURE 1. 9830 Vent-Free Pedestal
GasHeater.
4