GAS CONNECTION

The gasinletconnectionis3/8"NPT,madeat therearofthemaincontrolthroughtheareaat therearofthepedestal.

Test all gas joints from the gas meter to the heaterforleaksusingsoapandwatersolution after completing connection. DO NOT USE AN OPEN FLAME.

Gas Inlet Connection (3/8" NPT)

FIGURE 5. Rear View of 9830 Vent-Free Gas Heater

GAS PRESSURE CHECK

Theheaterregulatorcontrolstheburnerpressurewhichshouldbecheckedatthepressuretestpointlocatedonthe right side of the main control and is accessible from the side of the gas log assembly (see FIGURE 6).

The pressure should be checked with the heater burning and the control set to high (HI).

The pressure regulator is preset and locked to avoid tampering. If the pressure is not as specified in Product Specifications(Page5),contactyourdealerandreplacetheregulator.

Control Bracket (Rightside view facing heater)

Test Pressure

 

Input

Test Pressure

 

 

Output

 

Control Valve

 

FIGURE 6. Pressure Test Point Location