ADJUSTMENTS AND TESTING

WHITEBLACK

BARE

GREEN

(IF SUPPLIED)

4.With the gasket in place against the cover, place two mounting screws through the security floodlight cover and through the gasket.

5.Tuck wires into the electrical box and start the screws into the electrical box. Inspect to ensure that all wires are inside of the box (not pinched) and the gasket is in place. Secure the security floodlight to the electrical box.

ADJUSTMENTS AND TESTING

Four easy adjustment and testing steps put your security floodlight into operation: sensor and floodlight positioning, test, timing adjustment and sensitivity adjustment. You can make these adjustments and tests in daylight. After a few days of operation, you may want to make readjustments - refer to FINAL ADJUSTMENTS.

Sensor and Floodlight Positioning

Position the sensor for correct operation and position the floodlights to light the desired areas.

CAUTION

Do not point the sensor above the horizon because it may be damaged from direct sunlight.

For Wall/Eave Mounting

1.Loosen the sensor head locknut and loosen the elbow joint screw.

2.Position the sensor horizontally (controls facing downward) towards the desired target area.

SENSOR HEAD

LOCKNUT