Universal HE-117, HE-112 Operation Where A Wall Switch Is Not Installed, Final Adjustments

Models: HE-117W HE-100BW HE-117-2B HE-112W HE-100B HE-112 HE-117

1 8
Download 8 pages 43.59 Kb
Page 7
Image 7
Automatic Operation

The floodlight remains on the set time between 5 seconds and 18 minutes (approximate).

The manual mode permits you to turn the security floodlight on for as long a time period as you desire. You end the on-time by manually turning the security floodlight off and then back on after 5 seconds (the security floodlight is now in the automatic mode). In the manual mode, the light sensor, infrared sensor and the timer are disabled.

If the wall switch is set to off continuously, the security floodlight does not operate at any time.

Automatic Operation

To place the security floodlight in the automatic mode, turn the wall switch off, then turn it back on after 5 seconds or longer. The security floodlight will come on for the time duration set and then turn off. You may now leave the wall switch on continuously. The security floodlight will only come on in darkness when it detects something in the pattern and will go off at the end of the time period.

Manual Operation

To place the security floodlight in the manual mode so that the security floodlight will remain on continuously (for example, if you're having an outdoor party), turn the wall switch off and then on again immediately (in less than 2 seconds). If the wall switch had been off, turn the switch on for 5 seconds or longer and then turn off and immediately on again.

OPERATION WHERE A WALL SWITCH IS NOT INSTALLED

If a wall switch is not installed, your security floodlight operates in the automatic mode only. The system is always controlled by the solid- state circuits in the sensor. The security floodlight will only come on in darkness when it detects something in the pattern and it will shut off at the end of the time period.

NOTE

By using the existing circuit breaker, the security light can be operated in a "manual"

mode much the same as in the manual mode when a wall switch is installed.

Set the circuit breaker controlling power to the security floodlight to off and then immediately on (in less than 2 seconds); the floodlights will remain on. To reset the security floodlight to automatic operation again, set the circuit breaker off and set the breaker to on again after 5 seconds or longer. The floodlights will come on for the set time duration then go off and remain in the automatic mode.

FINAL ADJUSTMENTS

Once the security floodlight has operated for several days, you may want to make several final adjustments: sensitivity, duration of on- time and activation prior to complete darkness. Make these adjustments as follows:

Sensitivity (SENS/RANGE)

If family pets or other interference cause the security floodlight to come on, make the floodlight less sensitive. Turn the SENS/ RANGE control counterclockwise to make the floodlight less sensitive (or clockwise to make it more sensitive).

Duration of On-Time

The on-time of the security floodlight is variable from 5 seconds to about 18 minutes. Turn the TIME control clockwise to increase the on-time. Turn the TIME control counterclockwise to decrease the on -time.

Activation Prior to Complete Darkness

If you want the security floodlight to activate at dusk instead of complete darkness, turn the DAYLIGHT/TEST-ON control a small distance counterclockwise.

Page 7
Image 7
Universal HE-117 Operation Where A Wall Switch Is Not Installed, Final Adjustments, Automatic Operation, Manual Operation