PART 2 Electrical Connection
WARNING!
Ensure that the power supply is disconnected before proceeding. Verify that the power supply matches the ratings found on the appliance data label before proceeding. The complete appliance must be properly grounded at all times when electrical power is applied. Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized. Failure to complete electrical connections properly may result in damaged or
It is the owner’s responsibility to ensure that a qualified person performs the electrical connection of this appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA
National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts
INSTRUCTIONS:
A 15 to 20 amp electrical service is recommended for proper electrical supply. Always observe local building codes. Always use a dedicated circuit. The
Wire connections: (See Diagram Below)
There are 3 wires on the front panel that require connection.
BLACK WHITE GREEN
120 VAC from electrical panel (usually black) Neutral from electrical panel (white)
Ground from electrical panel (usually green)
CAUTION:
The neutral wire (white) must only be connected to the white neutral wire coming in from the electrical panel.
House Electrical
Panel
Green
White
120V Black (L)
Hood
BLK
WHT
GRN