MAINTENANCE OF YOUR WATER HEATER

MAINTENANCE OF YOUR WATER HEATER

Temperature and Pressure Relief Valve

Draining and FlushingWARNING

Explosion Hazard

If the temperature and pressure relief valve is dripping or leaking, have a qualified person replace it.

Examples of a qualified person include: licensed plumbers, authorized electric company personnel, and authorized service personnel.

Do not plug valve. Do not remove valve.

Failure to follow these instructions can result in death or explosion.

Manually operate the temperature and pressure relief valve at least once a year to make sure it is working properly.

To prevent water

 

 

 

 

 

 

 

damage, the valve

Figure 11

must be properly

 

 

Temperature and Pressure

 

connected to a

 

 

Relief Valve

 

 

 

 

 

 

Manual Relief

 

 

 

 

 

 

discharge line which

 

 

 

 

 

 

Valve

terminates at an

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adequate drain.

 

 

 

 

 

 

 

Standing clear of the

 

 

 

 

 

 

 

outlet (discharged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

water may be

 

 

 

 

 

 

 

hot), slowly lift and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

release the lever

 

 

 

 

 

 

 

Discharge line to drain

handle on the

temperature and

 

 

 

 

 

 

 

pressure relief valve to allow the valve to operate freely and return to its closed position. If the valve fails to completely reset and continues to release water, immediately disconnect the electrical power, close the cold water inlet valve and call a qualified person.

Draining and Flushing

It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during operation. The water heater should be drained if being shut down during freezing temperatures. To drain the tank, perform the following steps:

1.Place the water heater in Standby Mode by pressing the power button on the user interface module.

2.Turn off the power to the water heater at the circuit breaker/fuse box.

3.Open a nearby hot water faucet until the water is no longer hot.

4.Close the cold water inlet valve.

5.Connect a hose to the drain valve and terminate it to an adequate drain or external to the building.

6.Open the water heater drain valve and allow all of the water to drain from the tank. Flush the tank with water as needed to remove sediment.

7.Close the drain valve, refill the tank (open the cold water inlet valve), and restart the heater as directed in this manual.

IMPORTANT: Do not turn on power to the water heater unless it is completely filled with water. To ensure that the tank is full, open a hot water faucet and allow the water to run until the air is purged and the water flows uninterrupted from the faucet.

8.Press the power button to turn the water heater on. NOTE: The water heater will conduct a system diagnostic prior to operation.

If the water heater is going to be shut down for an extended period, the drain valve should be left open.

Heating Element Replacement

Heating Element ReplacementWARNING

Electric Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Replacement heating elements must be of the same style and voltage/wattage rating as the ones originally in the water heater. This information can be found on the flange or terminal block of the element or on the water heater data plate.

IMPORTANT: Before replacing any element confirm that you have the correct replacement element (wattage). This water heater has a 4500 watt upper element and a 2000 watt lower element. DO NOT replace the element(s) with a wattage different than the ones specified for the upper and/ or lower element.

IMPORTANT: Using an element greater than 2000 watts in place of the lower element will damage the water heater and void the warranty.

1.Press the power button on the user interface module to place the water heater in Standby Mode.

2.Turn off the power to the water heater.

3.Drain the water heater as directed in the “Draining and Flushing” section.