Vanguard Heating VMH26TPB installation manual Inspecting Burner, Pilot Flame Pattern

Models: VMH26TPB

1 36
Download 36 pages 27.43 Kb
Page 23
Image 23
INSPECTING BURNER

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

Thermocouple

Pilot Burner

 

Figure 24 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

Figure 25 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 25

turn fireplace off (see To Turn Off Gas to Appliance, page 22).

see Troubleshooting, pages 25 through 28.

23

102886