Vanguard Heating VP2000BB, VGP30B installation manual Checking Gas Connections, Continued

Models: VGP30B VP2000BB

1 32
Download 32 pages 6.51 Kb
Page 16
Image 16
PRESSURE TESTING HEATER GAS CONNECTIONS

CHECKING GAS CONNECTIONS

Continued

3.Pressurize supply piping system by either using compressed air or opening propane supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Figure 14).

2.Pressurize supply piping system by either using compressed air or opening propane supply tank valve.

3.Check all joints from propane supply tank to manual shutoff valve (see Figure 13). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open manual shutoff valve (see Figure 14).

2.Open propane supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 17 through 19). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 19).

8.Replace front panel.

Open

Manual

Shutoff

Valve

Closed

Figure 14 - Manual Shutoff Valve

Propane Supply Tank

Control Valve Location

Manual

Shutoff

Valve

16

Figure 15 - Checking Gas Joints

100100

Page 16
Image 16
Vanguard Heating VP2000BB, VGP30B Checking Gas Connections, Continued, Pressure Testing Heater Gas Connections