Vanguard Heating VGP30B, VP2000BB Technical Service, Service Hints, Specifications

Models: VGP30B VP2000BB

1 32
Download 32 pages 6.51 Kb
Page 25
Image 25
TECHNICAL

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

VGP30B

VP2000BB

BTU (Variable)

15,000/30,000

9,000/18,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

 

Heater

23.5 x 25.9 x 8.0

23.5 x 18.5 x 8.0

Carton

25.8 x 28.7 x 10.1

25.8 x 21.3 x 10.1

Weight (pounds)

 

 

Heater

30

22

Shipping

35

27

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.