UNVENTED NATURAL GAS FIREPLACE

OPERATING

FIREPLACE

Thermostat-Controlled Models

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.

This appliance has a pilot which must

 

be lighted by hand. When lighting the

 

pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

 

around the appliance area for gas. Be

 

sure to smell next to the floor because

 

some gas is heavier than air and will

 

settle on the floor.

 

WHAT TO DO IF YOU SMELL

 

GAS

 

• Do not try to light any appliance.

 

• Do not touch any electric switch; do

 

not use any phone in your building.

 

• Immediately call your gas supplier

 

from a neighbor’s phone. Follow

 

the gas supplier’s instructions.

 

• If you cannot reach your gas sup-

 

plier, call the fire department.

C. Use only your hand to push in or turn

 

the gas control knob. Never use tools.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1. STOP! Read the safety information in column 1.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position (see Figure 27).

4. Wait five (5) minutes to clear out any

gas. Then smell for gas, including

near the floor. If you smell gas,

STOP! Follow “B” in the safety in-

formation, column 1. If you don’t

smell gas, go to the next step.

5. Turn control knob counterclockwise

C-clockwiseto the PILOT position. Press

in control knob for five (5) seconds

(see Figure 27).

Note: If running fireplace for first

time, there will be air in gas line. You

6.Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 15.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Electrode

If the knob will not push in or turn

by hand, don’t try to repair it, call a

qualified service technician or gas

supplier. Force or attempted repair

may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately

call a qualified service technician to

inspect the appliance and to replace

any part of the control system and

may need to press in control knob for

30 seconds or longer. This will allow

air to bleed from the gas system.

Ignitor Button

Thermocouple

Pilot Burner

any gas control which has been un-

der water.

Control Knob

Figure 27 - Control Knob and Ignitor Button Location

Figure 28 - Pilot

Continued

For more information, visit www.desatech.com

14

107157

Page 14
Image 14
Vanguard Heating VSGF28NVA, VSGF28NTC Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions