UNVENTED NATURAL GAS FIREPLACE

OPERATING

FIREPLACE

Continued

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Slightly depress and turn control

knob counterclockwise C-clockwiseto the HIGH position. Both burners should light. Set control knob to ei- ther HIGH or LOW.

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glowing em- bers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort.

WARNING: Do not operate heater between locked positions.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 15.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 1.

Control Knob

IGNITOR

Ignitor Button

Figure 29 - Control Knob and Ignitor Button Location

Ignitor Electrode

Thermocouple

Pilot Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise Clockwise to the HIGH position.

2.Slightly depress control knob and

turn clockwise Clockwise to the PILOT position.

3.Slightly depress control knob and

turn clockwise Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1.Turn control knob clockwise to the HIGH position.

2.Press in and turn clockwise to the PILOT position.

Clockwise

Clockwise

Figure 30 - Pilot

Continued