Vanguard Heating VYS24PWA To Turn Off Gas To Appliance, Manual Lighting Procedure, Continued

Models: VYS24PWA VYS18PWA VYS30PWA

1 26
Download 26 pages 40.58 Kb
Page 15
Image 15
TO TURN OFF GAS

OWNER’S MANUAL

OPERATING

HEATER

Continued

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control

knob counterclockwiseShutting Off Heater to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burner. Note:AUTO is only functional when using GWMT1 or GWMS2 op- tional accessories.

11.Set flame adjustment knob to any level between HI and LO.

Shutting Off Burner Only (pilot stays lit) CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

MANUAL LIGHTING WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor

OPTIONAL REMOTE Electrode

Figure 21- Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Thermostat Control Operation to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to prevent draining battery.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burner and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise GHRC Series Operation: to the PILOT position.

2.Use remote control manual OFF button.

3.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Light- ing Instructions, page 14.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, column 1.

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 24). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off auto- matically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

For wall thermostat operation, follow in- struction supplied with thermostat acces- sory GWMT1. For wall switch operation follow instructions supplied with GWMS2.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 14.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. Note: The burner may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 sec- onds to assure proper operation.

GHRC Series Operation:

2a. Press ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.

GHRCTA Series Operation:

2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 22, page 16). The lights to the left of the button will show AUTO, ON, or OFF.

In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.

In the AUTO mode, the thermostat in the hand-held remote unit con- trols the room temperature. To in- crease the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer.

Continued

105190

15

Page 15
Image 15
Vanguard Heating VYS24PWA To Turn Off Gas To Appliance, Manual Lighting Procedure, Optional Remote Operation, Continued