Vanguard Heating VYS24PWA, VYS30PWA Mantel Clearances, Floor Clearances, Installation, Continued

Models: VYS24PWA VYS18PWA VYS30PWA

1 26
Download 26 pages 40.58 Kb
Page 9
Image 9
MANTEL CLEARANCES

OWNER’S MANUAL

INSTALLATION

Continued

MANTEL CLEARANCES

In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

12"

 

 

 

 

 

 

8"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

8"

 

14"

17"

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

24"

Log Set

24” and 30” Models

 

20" FLOOR CLEARANCES 18" Model

Top of Fireplace

Opening

Determining Minimum Mantel Clearance When using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clear- ances shown in Figure 7 when using hood.

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Shelf

NOTICE: Surface temperatures of adjacent walls and mantels be- come hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these tempera- tures meet the requirement of the national product standard. Fol- low all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

12"

10"

8"

6"

2 1/2"

Minimum Non-

Combustible

Material

8"

Min.

Hood

(GA6050, GA6052, or GA6053)

12"

15"

 

 

Distances to Underside of Mantel

18"

Underside of

Mantel Shelf

All minimum distances are in inches

20"

Top of Fireplace

Opening

operate the logs only with the flue damper open

raise the mantel to an accept- able height

remove the mantel

Figure 7 - Minimum Mantel Clearances When Using Hood

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combus- tible flooring (see Figure 9).

 

Combustible

Hearth Combustible

14"

Material

Min.

 

5”

Material

 

 

 

 

 

Min.

 

Noncombustible Material

 

 

Figure 8 - Minimum Fireplace Clearances

Figure 9 - Minimum Fireplace Clearances

If Installed at Floor Level

 

Above Combustible Flooring

Continued

105190

9

Page 9
Image 9