Sun Microsystems T6320 service manual DIMM Installation Rules, When Replacing Faulty FB-DIMMs

Models: T6320

1 150
Download 150 pages 45.06 Kb
Page 34
Image 34
When Replacing Faulty FB-DIMMs

When Replacing Faulty FB-DIMMs

Within each branch, ensure that the replacement FB-DIMM has the same part number as the FB-DIMM you are removing. If you are unable to obtain an FB-DIMM with the same part number, you might need to replace all FB-DIMMs in the branch to ensure that they all have the same part number.

The following table lists the supported FB-DIMMs and part numbers.

TABLE 2 Supported FB-DIMMs and Part Numbers

Description

 

Ordered Separately

Assembled at Factory

 

 

 

 

FB-DIMMs Supported at November 2007 Release of the Server Module

 

1

GB single rank x4 FB-DIMM x 2

(2 GB FB-DIMM Memory Kit)

X4200A

4200A

2

GB single rank x4 FB-DIMM x 2

(4 GB FB-DIMM Memory Kit)

X4203A

4203A

4

GB dual rank x8 DIMM x 2 (8 GB FB-DIMM Memory Kit)

X4204A

4204A

 

FB-DIMMs Added at October 2008 Release of the Server Module

 

 

1

GB dual rank x8 FB-DIMM x 2

(2 GB FB-DIMM Memory Kit)

X4200AF

4200AF

2

GB dual rank x8 FB-DIMM x 2

(4 GB FB-DIMM Memory Kit)

X4203AF

4203AF

8

GB dual rank x8 FB-DIMM x 2

(16 GB FB-DIMM Memory Kit)

X4290AF

4290AF

 

 

 

 

 

2.2.1.1DIMM Installation Rules

Caution – The following FB-DIMM rules must be followed. The server module might not operate correctly if the FB-DIMM rules are not followed. Always use DIMMs that have been qualified by Sun.

FB-DIMMs must be installed in groups of four, each of the same capacity.

The following configurations are supported in the Sun Blade T6320 server module:

Four FB-DIMMs (Group 1) Channel 0, FB-DIMM connector 0 in all branches must be populated.

Eight FB-DIMMs (Groups 1 and 2)

Sixteen FB-DIMMs (Groups 1, 2 and 3)

See Section 4.3.1, “Removing the DIMMs” on page 4-10 for FB-DIMM installation instructions. FIGURE 2-3shows where to to install FB-DIMMs in groups of four.

2-8Sun Blade T6320 Server Module Service Manual • June 2009