Sun Microsystems T6320 service manual Changing POST Parameters, Select the Diagnostics Tab

Models: T6320

1 150
Download 150 pages 45.06 Kb
Page 59
Image 59
2.6.2Changing POST Parameters

TABLE 2-7shows typical combinations of ILOM variables and associated POST modes.

TABLE 2-7POST Modes and Parameter Settings

 

Normal Diagnostic Mode

 

Diagnostic Service

Keyswitch Diagnostic

Parameter

(default settings)

No POST Execution

Mode

Preset Values

 

 

 

 

 

diag_mode

normal

off

service

normal

setkeyswitch*

normal

normal

normal

diag

diag_level

min

n/a

max

max

diag_trigger

power-on-reset

none

all-resets

all-resets

 

error-reset

 

 

 

diag_verbosity

Description of POST execution

normal

n/a

max

max

This is the default POST

POST does not

POST runs the full

POST runs the full

configuration. This

run, resulting in

spectrum of tests

spectrum of tests

configuration tests the

quick system

with the maximum

with the maximum

system thoroughly, and

initialization, but

output displayed.

output displayed.

suppresses some of the

this is not a

 

 

detailed POST output.

suggested

 

 

 

configuration.

 

 

* The setkeyswitch parameter, when set to diag, overrides all the other POST variables.

2.6.2Changing POST Parameters

You can use the web interface or the CLI to change the POST parameters.

2.6.2.1Using the Web Interface to Change POST Parameters

1.From the ILOM web interface, select the Remote Console tab (FIGURE 2-17).

2.Select the Diagnostics Tab.

3.Select the POST settings that you require.

TABLE 2-7describes how the POST settings will execute.

4.Click the Save button.

Note – If you do not have a console window open, you should open one. POST will only display output to a console window, not the web interface.

Chapter 2 Sun Blade T6320 Server Module Diagnostics 2-33

Page 59
Image 59
Sun Microsystems T6320 Changing POST Parameters, Using the Web Interface to Change POST Parameters, Click the Save button