Sun Microsystems T6320 service manual Identifying Faults With the fmadm faulty and fmdump Commands

Models: T6320

1 150
Download 150 pages 45.06 Kb
Page 68
Image 68
2.7.1Identifying Faults With the fmadm faulty and fmdump Commands

The Predictive Self-Healing technology covers the following Sun Blade T6320 server module components:

UltraSPARC® T2 multicore processor (CPU)

Memory

I/O bus

The PSH console message provides the following information:

Type

Severity

Description

Automated response

Impact

Suggested action for system administrator

If the Solaris PSH facility has detected a faulty component, type the fmdump command to identify the fault. Faulty FRUs are identified in fault messages using the FRU name. For a list of FRU names, see Appendix A.

Note – Additional Predictive Self-Healing information is available at:

http://www.sun.com/msg

2.7.1Identifying Faults With the fmadm faulty and fmdump Commands

2.7.1.1Using the fmadm faulty Command

Type the fmadm faulty command to identify a faulty component.

1.Type fmadm faulty.

#fmdadm faulty

STATE RESOURCE /UUID

faulted cpu:///cpuid=8/serial=FAC006AE4515C47 8856153f-6f9b-47c6-909a-b05180f53c07

The output shows the UUID of the related fault and provides information for clearing the fault.

2-42Sun Blade T6320 Server Module Service Manual • June 2009

Page 68
Image 68
Sun Microsystems T6320 Identifying Faults With the fmadm faulty and fmdump Commands, Using the fmadm faulty Command