Sun Microsystems T6320 Clearing POST Detected Faults, Commands” on page, show /SP/faultmgmt

Models: T6320

1 150
Download 150 pages 45.06 Kb
Page 64
Image 64
2.6.4Clearing POST Detected Faults

2.Type the show /SPfaultmgmt command to obtain additional fault information.

The fault is captured by ILOM, where the fault is logged. The Service Action Required LED is lit, and the faulty component is disabled.

For example:

ok #. ->

->show /SP/faultmgmt

/SP/faultmgmt

Targets:

0(/SYS/MB/CMP0/BR2/CH1/D1)

Properties:

Commands: cd show

In this example, /SYS/MB/CMP0/BR2/CH1/D1 is disabled. The system can boot using memory that was not disabled until the faulty component is replaced.

Note – You can use ASR commands to display and control disabled components. See Section 2.9, “Managing Components With Automatic System Recovery Commands” on page 2-48.

2.6.4Clearing POST Detected Faults

In most cases, when POST detects a faulty component, POST logs the fault and automatically takes the failed component out of operation by placing the component in the ASR blacklist.

See Section 2.9, “Managing Components With Automatic System Recovery

Commands” on page 2-48).

After the faulty FRU is replaced, you must clear the fault by removing the component from the ASR blacklist.

2-38Sun Blade T6320 Server Module Service Manual • June 2009

Page 64
Image 64
Sun Microsystems T6320 Clearing POST Detected Faults, See .9, “Managing Components With Automatic System Recovery