Sun Microsystems T6320 service manual Open the ejector levers FIGURE

Models: T6320

1 150
Download 150 pages 45.06 Kb
Page 96
Image 96
4. Open the ejector levers (FIGURE 4-3).

Caution – The cable dongle is for temporary connections only. The cable dongle has not been evaluated for electromagnetic compatibility (EMC). The cable dongle or server module connectors could be damaged by rack doors or other impacts. Remove the cable dongle during normal system operation.

Note – If you are using the older 4-cable dongle (UCP-4), do not use the RJ-45 connector with the Sun Blade T6320 server module. Use the DB-9 connector for serial connections.

4. Open the ejector levers (FIGURE 4-3).

FIGURE 4-3Removing the Sun Blade T6320 Server Module From the Chassis

5.While pinching the release latches, slowly pull the server module forward until the slide rails latch.

4-8Sun Blade T6320 Server Module Service Manual • June 2009