2.5.2Changing POST Settings With the ILOM CLI

2.5.2Changing POST Settings With the ILOM CLI

1. Type the show command to see the current POST settings:

->show /HOST/diag /HOST/diag

Targets Properties:

level = max mode = normal

trigger = power-on-reset error-reset verbosity = normal

Commands: cd set show

2.Change the POST settings with the set /HOST/diag command. For example:

-> set /HOST/diag level=min Set ’level’ to ’min’

-> set /HOST/diag mode=Normal Set ’mode’ to ’Normal’

-> set /HOST/diag verbosity=max Set ’verbosity’ to ’max’

-> set /HOST/diag trigger=power-on-resettrigger=error-reset Set ’trigger’ to ’power-on-reset’

Set ’trigger’ to ’error-reset’

2.5.3Displaying System Faults

ILOM displays the following faults with the web interface and CLI:

Environmental faults – Temperature or voltage problems that might be caused by faulty FRUs (power supplies, fans, or blower), or by room temperature or blocked air flow.

POST detected faults – Detected by the power-on self-test diagnostics.

PSH detected faults – Detected by the Solaris Predictive Self-healing (PSH) technology