Sun Microsystems T6320 service manual FB-DIMM Configuration

Models: T6320

1 150
Download 150 pages 45.06 Kb
Page 101
Image 101
FB-DIMM Configuration

TABLE 4-2

FB-DIMM Configuration

 

 

 

 

 

 

 

 

 

 

 

 

Motherboard

FB-DIMM

 

 

 

 

FB-DIMM

Installation

FB-DIMM

Branch Name

Channel Name

FRU Name

Connector

Order*

Pair\

 

Channel 1

/SYS/MB/CMP0/BR0/CH1/D0

J1201

2

A

 

 

/SYS/MB/CMP0/BR0/CH1/D1

J1301

3

B

Branch 1

Channel 0

/SYS/MB/CMP0/BR1/CH0/D0

J1401

1

C

 

 

/SYS/MB/CMP0/BR1/CH0/D1

J1501

3

D

 

Channel 1

/SYS/MB/CMP0/BR1/CH1/D0

J1601

2

C

 

 

/SYS/MB/CMP0/BR1/CH1/D1

J1701

3

D

Branch 2

Channel 0

/SYS/MB/CMP0/BR2/CH0/D0

J2001

1

E

 

 

/SYS/MB/CMP0/BR2/CH0/D1

J2101

3

F

 

Channel 1

/SYS/MB/CMP0/BR2/CH1/D0

J2201

2

E

 

 

/SYS/MB/CMP0/BR2/CH1/D1

J2301

3

F

Branch 3

Channel 0

/SYS/MB/CMP0/BR3/CH0/D0

J2401

1

G

 

 

/SYS/MB/CMP0/BR3/CH0/D1

J2501

3

H

 

Channel 1

/SYS/MB/CMP0/BR3/CH1/D0

J2601

2

G

 

 

/SYS/MB/CMP0/BR3/CH1/D1

J2701

3

H

 

 

 

 

 

 

*Upgrade path: DIMMs should be added with each group populated in the order shown. \ Fault replacement path: Each pair is addressed as a unit, and each pair must be identical.

Note – FB-DIMM names in ILOM messages are displayed with the full name, such as /SYS/MB/CMP0/BR0/CH0/D0.

3.Note the DIMM locations so that you can install the replacement DIMMs in the same sockets.

4.Push down on the ejector levers on each side of the DIMM connector until the DIMM is released.

Chapter 4 Replacing Cold-Swappable Components 4-13

Page 101
Image 101
Sun Microsystems T6320 service manual FB-DIMM Configuration