Vanguard Heating VYS18PWA Wiring Diagram, Specifications, Replacement Parts, Service Hints

Models: VYS24PWA VYS18PWA VYS30PWA

1 26
Download 26 pages 40.58 Kb
Page 20
Image 20
WIRING DIAGRAM

VANGUARD

UNVENTED PROPANE/LP GAS LOG HEATER

WIRING DIAGRAM

Note: For proper operation of optional ac- cessories, the wires from the switch to the control must be connected exactly as shown.

OFF

ON

Thermopile

SPECIFICATIONS

Vintage Oak

Vintage Oak

18"

24” and 30”

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-866-672-6040. When calling DESA International, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Btu (Variable)

17,500/27,000

19,000/31,500

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Manifold

8.0" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

 

Maximum

14"

14"

Minimum*

11"

11"

Shipping Weight

28 lbs.

30 lbs. (24")/32 lbs. (30")/

* For input adjustment

 

 

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this prod- uct. If they can’t supply original replace- ment part(s), call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040.

You can also visit DESA International’s technical services web site at www.desatech.com.