BHDV34NB AND BHDV34PB

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

PRE-INSTALLATION PREPARATION

CLEARANCES

Minimum clearances to combustibles for the fireplace are as follows:

Must maintain a minimum 1" clearance to combustibles

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient loca- tion for your Vanguard direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common loca- tions. Read all venting information in this manual. Be aware of all restrictions and precautions before deciding the exact loca- tion for your fireplace.

When deciding the location of your fire- place, follow these rules:

1.Do not connect this fireplace to a chim- ney flue serving a separate solid-fuel burning fireplace or appliance.

2.Due to high temperatures, do not lo- cate this fireplace in high traffic areas or near furniture or draperies.

3.Proper clearances must be maintained.

4.If your fireplace is to be installed di- rectly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Flush with a wall

Through exterior wall enclosed in a chase

Corner installation

Figure 2 - Common Fireplace Locations

 

 

 

 

RW

 

 

 

 

D

 

 

 

 

 

 

 

 

 

FW

 

 

 

 

 

 

 

 

 

 

 

Fireplace size

 

D x FW x RW

34"

 

 

18 1/2"

34 3/8"

14"

Back, and sides

0"/mm

Perpendicular walls

6" (152mm)

Floor

0"/mm

Ceiling to louver opening

42" (1067mm)

Front

36" (914mm)

Top of Standoffs

0"/mm

See General Venting on page 5 for specific venting clearances.

FRAMING AND FINISHING

Figures 4 and 5 show typical framing of this fireplace. Figure 6 on page 5 shows framing for corner installation. All minimum clear- ances must be met. Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fire- place must set on a metal or wood panel extending the full width and depth of the fireplace.

See Accessories on pages 34 and 35 for mantel kits available for this fireplace. If you are using a separate combustible mantel piece, refer to Figure 7 on page 5 for proper instal- lation height. You can install noncombustible mantels at any height above the fireplace. Note:Noncombustible mantels may discolor!

341/4"

343/4"

34"

20"

5/8" for drywall facing

Figure 5 - Framing Clearances for Typical Fireplace Installation

20" Vertical Termination

19" Horizontal Termination

Figure 3 - Fireplace Bottom Dimensions

Figure 4 - Framing Clearances for Installation Against an Exterior Wall

4