TECHNICAL
SERVICE
SPECIFICATIONS
SERVICE
HINTS
24
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at
BTU (Variable) | 5,000/10,000 |
Type Gas | Propane Only |
Ignition | Piezo |
Pressure Regulator Setting | 8" W.C. |
Inlet Gas Pressure (inches of water) |
|
Maximum | 14" |
Minimum | 11" |
Dimensions, Inches (H x W x D) |
|
Heater | 20 1/2 x 13 1/2 x 5 |
Carton | 25 x 16 11/16 x 7 1/2 |
Weight (pounds) |
|
Heater | 13.5 |
Shipping | 16.5 |
When gas pressure is too low
•pilot will not stay lit
•burner will have delayed ignition
•heater will not produce specified heat
•propane gas supply may be low
When gas quality is bad
•pilot will not stay lit
•burner will produce flames and soot
•heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.
099406