A

In the electronics fail.

A

D

B

C

It is possible to bypass the control system if the electronics fail.

Please note, when the system is bypassed, the safety devices do not operate. Extreme care should be taken when operating the mixer.

1.Switch off the main power.

2.Open the top lid, flip the dip switch (B) on the back of the computer control from “Auto” to “Manual”.(NOTE: The front L.E.D. lights will not display in “Manual” mode)

3.Disconnect the “Speed Reg” Harness(C).

4.Disconnect the servo motor by removing the cotter pin (A) the the clevis pin.

5.Remove the round black plug button on the right side of the mixer, and insert the auxillary speed lever (D) into the slotted shaft.

6.Close the lid, turn on the power.

7.Only 2 buttons will function, the START key and emergency stop button. Start the mixer and use the auxillary lever to adjust the speed.