Vector VEC018 RECHARGING THE Pocket Generator, Recharging From A 110-volt AC Power Source

Models: VEC018

1 8
Download 8 pages 29.17 Kb
Page 4
Image 4
RECHARGING THE Pocket Generator™

6.WARNING: Do not run both AC and DC devices at the same time.

7.ALWAYS turn OFF the Power Force 50™ inverter BEFORE charging the Pocket Generator™.

8.The nylon case that is provided with the Pocket Generator™ is water-resistant only to the extent that it will help protect the unit from rain or water spray; never immerse the unit in water (fresh or salt).

9.Do not expose the Pocket Generator™ to extreme heat or flames.

10.Do not exceed recommended charging times.

11.Continuous run times are limited, see charts for estimated operation times.

RECHARGING THE Pocket Generator™

CAUTION:

IMPORTANT: Before recharging from an AC power source, verify that the source is 110 volts only. Do not plug this unit’s 110 volt charger into a 220 volt power source.

IMPORTANT: Be sure that power inverter ON/OFF switch is in OFF position before recharging.

Recharging From A 110-volt AC Power Source

1.Before initial use, it will take 18-20 hours to fully charge the Pocket Generator™. Subsequent charges will only take 12-15 hours (approx.).

2.Insert the cigarette lighter plug at the end of the AC charger cord into the matching 12 volt receptacle on the side of the Pocket Generator™.

3.Plug the charger into any standard 110/120 volt AC electrical outlet. Never plug a 110 volt charger into a 220 volt power source.

Recharging From A 12 volt DC Power Source

CAUTION:

Do not connect the Pocket Generator™ DC charger to a car or boat electrical system (12 volt DC negative-ground only) without first starting the engine. Failure to do so could damage the vehicle’s battery.

1.Insert the cigarette lighter plug at one end of the DC charger cord into the matching 12 volt receptacle on the side of the Pocket Generator™.

2.Insert the cigarette lighter plug at the other end of the cord into the vehicle’s cigarette lighter receptacle. Rotate the plug slightly to ensure good contact. A green L.E.D. light on the cigarette plug will indicate a proper connection.

3.The Pocket Generator™ should be charged initially for 4-6 hours, while driving, before use. Subsequent charges should only require 2-4hours (approx.).

4.The DC charging system will not provide as full a charge as is obtained with a 110 volt charging system.

Battery Operating Time

1.Always turn power switch on the inverter to OFF position when unit is not in use. If the switch is left in the ON position, it will drain the Pocket Generator™ battery.

2.WARNING: Never run both AC and DC devices at the same time as this can damage the Pocket Generator™.

3.Always recharge unit after using.

With a full charge, the Power Force 50™ inverter will deliver a minimum operating time of 30 minutes to one hour. In most instances, 1-3 hours of operating time is achievable (see chart below).

Estimated Operation Times:

110-VOLT AC APPLIANCE

APPROX. RUNNING TIME

50 WATT LAMP

40 MINUTES

LAPTOP / PRINTER

1.5 HOURS

DESK FAN

2.0 HOURS

STEREO/CD PLAYER

2.5 HOURS

CELLULAR PHONE, POWER TOOLS

5 TO 10 HOURS

& CAMCORDER CHARGERS

 

TROUBLESHOOTING

Protective Features of the Power Force 50™

The Power Force 50™ monitors the following potentially hazardous conditions:

Low Battery Voltage - this condition is not harmful to the inverter but could damage the power source, so the inverter automatically shuts down when input voltage drops to 10.0 volts. When this condition is corrected, the unit may be restarted.

Over Voltage Protection - the Power Force 50™ will automatically shut down when the input voltage exceeds 15 volts DC.

Short Circuit Protection - Reverse polarity or a short circuit condition will usually result in failure of the inverter’s fuse. Immediately disconnect the shorted load and replace the fuse inside the Pocket Generator™.

3

 

 

 

12

 

 

Page 4
Image 4
Vector VEC018 RECHARGING THE Pocket Generator, Recharging From A 110-volt AC Power Source, Battery Operating Time