8.TROUBLESHOOTING GUIDE:

TABLE 1 - INVERTER POWER SWITCH TURNED ON

TROUBLE/ INDICATION

POSSIBLE CAUSE

SUGGESTED REMEDY

No AC output –

DC input below 10 volts

Recharge or replace

red LED lit

 

battery

 

 

 

No AC output –

Excessive appliance

Reduce load-wait for

red LED lit

load-thermal shutdown

inverter to cool. Turn OFF,

 

then turn ON

 

 

 

 

No AC output –

Inverter fuses open

Contact technical Support

Green LED not lit

 

toll free 866-584-5504

 

 

 

 

 

 

TROUBLE/ INDICATION

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

Low battery alarm

Bad connection or wiring

Tighten all DC

sounds continuously

 

connections

Low battery

Low battery voltage

Recharge battery.

alarm sounds

 

Remove load from

 

 

inverter while recharging

 

 

battery

Motorized power tool

Excessive start-up load

If appliance does not start,

 

won’t start

then appliance is drawing

 

 

excessive wattage and will

 

 

not work with inverter

Motorized power tool

Purely inductive load

Make the load not purely

does not operate at

 

inductive. Operate an

correct speed

 

incandescent lamp at

 

 

same time as motor

Television/Radio

Snow in picture, buzz

Keep inverter and

 

interference in speaker

antenna distant from

 

 

each other. Use shielded

 

 

antenna cable. Connect

 

 

antenna to amplifier

 

 

 