Vector VEC024 Installation, Maxx SST 400 Watt Output Waveform, Power Source Requirements

Models: VEC024

1 16
Download 16 pages 61.49 Kb
Page 6
Image 6

3.2 THE MAXX SST 400 WATT OUTPUT WAVEFORM

The AC output waveform of the MAXX 400 SST is known as “modified sine wave”. It is a waveform that has characteristics similar to the sine wave shape of utility power. This type of waveform is suitable for most AC loads, including linear and switching power supplies used in electronic equipment, transformers, and motors.

The modified sine wave produced by the MAXX 400 SST inverter has an RMS (root mean square) voltage of 110 volts, which is the same as standard household power. Most AC voltmeters (both digital and analog)

are sensitive to the average value of the waveform rather than the RMS value. They are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave. These meters will not read the RMS voltage of a modified sine wave correctly. They will read about 20 to 30 volts low when measuring the output of the inverter. For accurate measurement of the output voltage of this unit, use a true RMS reading voltmeter such as a Fluke 87, Fluke 8060A, Fluke 77/99 series, Beckman 4410, or Triplett 4200.

FIGURE 4 - Modified Sine Wave and Sine Wave Comparison

4.INSTALLATION

4.1 POWER SOURCE REQUIREMENTS

The power source must provide between 10.5 and 15.5 volts DC and must be able to supply the necessary current to operate the load. The power source may be a battery or a well-regulated DC power supply. To obtain a rough estimate of the current (in amperes) the power source must deliver, simply divide the power consumption of the load (in watts AC) by 10.

6

6

Page 6
Image 6
Vector VEC024 owner manual Installation, Maxx SST 400 Watt Output Waveform, Power Source Requirements