9.FUSE REPLACEMENT
If external fuses blow, (or breakers trip), then there is a short or overload in the DC wiring. Find and fix the problem before replacing the fuses (or resetting the breaker). After fuse replacement, reconnect the inverter.
This power inverter is equipped with multiple internal fuses. Normally, these fuses will not blow unless there is a serious problem inside the unit. Internal fuses are replaceable, however, only electronically knowledgeable people should attempt fuse replacement. If the unit is damaged during fuse replacement, the warranty may be voided. Vector recommends contacting Vector Technical Support for guidance. Based on experience, it is best to return the unit to Vector for repair. Vector Technical Support can be reached by calling toll free
10.SPECIFICATIONS
Output Connection | Dual North American Standard Receptacles |
Output Voltage | Approx 110 volt AC RMS 60 Hz |
Output Current | 3.6 amps |
Output Waveform | Modified Sine Wave (filtered) |
Input Voltage Range | 10.5 to 15.5 volt DC |
Low Voltage Alarm | 10.6 volt DC |
Low Voltage Shutdown | 10.0 volt DC |
No Load Input Current | 0.4 amps |
Input Fuses | Internal |
Input Cables: | One 12 volt DC Plug (up to 175 Watts) |
Battery Clip Cable | (up to 400 watts) |
Additional Protection | Overload, Over volt, Over temp |
Weight | 1.45 Lbs (.66 kg) |
Length | 6.0 in. (15.24 cm) |
Width | 6.0 in. (15.24 cm) |
Height | 2.0 in. (5.08 cm) |
11.WARRANTY
2 YEAR LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, Ltd., regarding this product. There are no other warranties, other than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original